Sometimes when you connect the device to long wires or long cables that have a resistance drop or a stray inductance, it could result in spikes or noise at the output.
RL = 10kohm is just open circuited to remove the noise.
CL biasing cap to ensure stable voltage is maintained and ripple is reduced.