Q
My customer needs the total harmonic distortion (THD) parameters of theAD8428. Do you have this data or can you give some comments on it?
A
Unfortunately, we decided not to specify THD parameters for this part. However,I can tell you that it typically performs similar to the AD8429 (somewhere
around -110dBc with a 10Vpp output voltage at 1 kHz). Bear in mind that these
are only typical parameters and therefore not guaranteed. Even then, the
customer can expect superior performance compared to any competitor in the
market.