Q
What is the offset voltage at +125? in this case (LFCSP)?
A
The datasheet specifications give an offset voltage at ambient temp 25C of 70uVtyp and a typical offset drift of 2.5uV per degree C over the temperature range
of -40C to +125C. This would give a typical offset voltage of 320uV at 125C.
For a max value, see the TcVos offset distribution in Fig 10 on the datasheet.