Analog.com Analog Dialogue Wiki 简体中文
EngineerZone
EngineerZone
  • Log In
  • Site
  • Search
  • User
  • Support

    Popular Forums

    • RF and Microwave
    • Power Management
    • Video
    • FPGA Reference Designs
    • Precision ADCs
    • Linux Software Drivers
    • SigmaDSP Processors & SigmaStudio Dev. Tool

    Product Forums

    • A2B
    • Amplifiers
    • Analog Microcontrollers
    • Clock and Timing
    • Data Converters
    • Direct Digital Synthesis (DDS)
    • Energy Monitoring and Metering
    • Interface and Isolation
    • MEMS Inertial Sensors
    • Processors and DSP
    • Switches/Multiplexers
    • Temperature Sensors
    • Voltage References
    View All

    Application Forums

    • Audio
    • Automated Test Equipment (ATE)
    • Condition-Based Monitoring
    • Depth, Perception & Ranging Technologies
    • Embedded Vision Sensing Library
    • Motor Control Hardware Platforms
    • Optical Sensing
    • Precision Technology Signal Chains Library
    • Video
    • Wireless Sensor Networks Reference Library

    Design Center Forums

    • ACE Evaluation Software
    • ADEF System Platforms
    • Design Tools and Calculators
    • FPGA Reference Designs
    • Linux Software Drivers
    • Microcontroller no-OS Drivers
    • Reference Designs
    • Signal Chain Power (SCP)
    • Software Interface Tools
    • System Demonstration Platform (SDP) Support
  • Learn

    Highlighted Webinar

    Robust Industrial Motor Encoder Signal Chain Solutions

    Recent Discussions

    • About the values of CurV1,2 displayed in the cursors frame of scopy.
    • Purpose of "Load" in Scopy signal generator configuration GUI
    • about the transient response experiment example of RL Circuit using adalm2000
    • Using ADALM1000 AIN and CHA as kelvin connection
    • I2C communication with ADALM2OOO Through Scopy

    Places

    • ADI Education Home
    • ADI Education China
    • ADI Education India
    • ADI Education Philippines
    • StudentZone (Analog Dialogue)
    • Virtual Classroom

    Latest Webinars

    • Robust Industrial Motor Encoder Signal Chain Solutions
    • Precision Low Power Measurement Solutions for Intelligent Edge
    • Advantages of Integrating Digital Power System Management (DPSM) into your Design
    • Optimizing GaN and GaAs RF Amplifier Performance Using Novel Biasing Techniques
    • Improving Switch-Mode Power Supplies Using Noise Cancelling Technology
    View All Webinars
  • Community Hub

    Challenge Yourself!

      KCC's Quizzes AQQ230 about a clock and angle puzzle
    View All

    Places

    • Community Help
    • Logic Lounge

    Resources

    • EZ Code of Conduct
    • Getting Started Guide
    • ADI: Words Matter
    • Community Help Videos
    View All
  • Blogs

    Highlighted Blogs

    Using Python To Control The Pluto Radio And Plot Data

     

    Resistance is NOT Futile

    Latest Blogs

    • What is The Continuity of Engineering?
    • Move Over Sensors: Actuators Are Entering The Smart Factory Stage
    • What To Call A Non-Compliant Item
    • How to Construct a Beamformer with the ADALM-PLUTO
    • Customize Your EZ Experience
    Read All Blogs

    ADI Blogs

    • EZ Spotlight
    • The Engineering Mind
  • Partners

    Electronic Design Services - PartnerZone

    • Boston Engineering
    • Calian, Advanced Technologies
    • Colorado Engineering Inc. (DBA CAES AT&E)
    • Clockworks Signal Processing
    • Epiq Solutions
    • Fidus
    • PalmSens
    • Richardson RFPD
    • Tri-Star Design, Inc.
    • VadaTech
    • Vanteon
    • X-Microwave
    View All
Operational Amplifiers
  • Amplifiers
Operational Amplifiers
Documents Why is it, that voltage feedback amplifiers seem to dominant the op amp landscape compared to current feedback amplifiers?
  • Forums
  • File Uploads
  • Docs/FAQs
  • Members
  • Tags
  • More
  • Cancel
  • OPERATIONAL AMPLIFIERS
  • +ADA4177: FAQ
  • +ADA4528: FAQ
  • +ADA4622: FAQ
  • +ADA4638: FAQ
  • +precision performance of an amplifier: FAQ
  • -voltage feedback amplifiers: FAQ
    • Why is it, that voltage feedback amplifiers seem to dominant the op amp landscape compared to current feedback amplifiers?

Why is it, that voltage feedback amplifiers seem to dominant the op amp landscape compared to current feedback amplifiers?

Why is it, that voltage feedback amplifiers seem to dominant the op amp landscape compared to current feedback amplifiers?

Some may argue when it comes to selecting an op amp, it's more of a personal preference or taste in amplifiers. That is probably why quite often engineers select voltage feedback (VFB) op amps over current feedback (CFB) op amps.

So why is that? Well I'm sure that there are lots of reasons, just the sheer numbers, there are a lot more VFB amplifiers than CFB to chose from, but another reason is education. In colleges most often voltage feedback is the standard that is taught in the classroom. Many of the op amp examples found in text books, labs or simulations focus on VFB. You'll find very few examples of CFB op amps described in college text books, and if you do, they will only be briefly mentioned.

Now we can’t possibly cover all the differences and options between current feedback and voltage feedback amplifiers here, but we can discuss a few key points. First the design equations used for voltage feedback amps work equally well for current feedback amps, so nothing new to learn there. Voltage feedback amplifiers have a fixed gain bandwidth product; current feedback amplifiers do not, so you can have high gain and high bandwidth with a CFB amp. Voltage feedback amps have two high input impedance nodes, current feedback amps only have one, the non-inverting input; the inverting input is a low impedance input. Voltage feedback amplifiers have "open loop gain"; current feedback amps have "open loop transimpedance". Current feedback amplifiers have very wide bandwidths and very high slew rates compared to VFB amps. The feedback resistor plays a large role in CFB amplifier stability, unlike voltage feedback amplifiers. This limits the choices of feedback resistor (the value can be found in the manufacturer's datasheet) it can also limit the value of the gain set resistor.

We've only scratched the surface here, regarding current and voltage feedback amplifiers. Current feedback amplifiers provide engineers with another powerful option when designing circuits. We have a great deal of additional information on current feedback and voltage feedback amplifiers which can be accessed by clicking on the links below.

http://www.analog.com/static/imported-files/tutorials/MT-034.pdf

http://www.analog.com/static/imported-files/tutorials/MT-058.pdf

http://www.analog.com/static/imported-files/tutorials/MT-060.pdf

http://www.analog.com/library/analogDialogue/Anniversary/22.html

http://www.analog.com/library/analogDialogue/Anniversary/23.html

  • Share
  • History
  • More
  • Cancel
Related
Recommended
Social
Quick Links
  • About ADI
  • ADI Signals+
  • Analog Dialogue
  • Careers
  • Contact us
  • Investor Relations
  • News Room
  • Quality & Reliability
  • Sales & Distribution
  • Incubators
Languages
  • English
  • 简体中文
  • 日本語
Newsletter

Interested in the latest news and articles about ADI products, design tools, training and events? Subscribe today!

Sign Up
Analog Logo
©1995 - 2023 Analog Devices, Inc. All Rights Reserved
沪ICP备09046653号-1
  • Sitemap
  • Legal
  • Privacy & Security
  • Privacy Settings
EngineerZone Uses cookies to ensure you get the best experience in our community. For more information on cookies, please read our Privacy & Security Statement.